- Product Description
-
- Commodity name: Heat Exchanger
● Standard Standard
China National Standard
GB5310-2017
American Society of Mechanical Engineers Standard
ASME SA-106 ASME SA -192MASME SA -209M
ASME SA-210M ASME SA -213MASME SA -335MGerman Industrial Standards
DIN17175
Japanese Industrial Standards
JIS G3462
● Uses
Used in the manufacture of boiler water walls, economizers, reheaters, superheaters and steam pipes
● Dimensional deviation Deviation
Deviation of wall thickness and outer diameter of steel pipe supplied according to GB5310 standard
Type of steel pipe
Size of steel pipe mm
Allowable deviation
Normal
Advanced
hot rolled tube
Outer diameter D
≤ 159
± 1.0% (minimum ± 0.5mm)
± 0.75% (minimum ± 0.3mm)
> 159
± 1.0%
± 0.90%
Wall thickness S
< 3.5
+ 15% (minimum +0.48 mm-10 -0.32mm)
± 10% (minimum ± 0.2mm)
3.5~20
+15%-10%
±10%
> 20
D < 219
± 10%
±7.5%
D ≥ 219
+12.5%-10.0%
±10%
cold drawn pipe
Outer diameter D
≤ 30
± 0.20mm
± 0.15mm
> 30~50
± 0.30mm
± 0.25mm
> 50
±0.8%
±0.6%
Wall thickness S
2~3
+12%-10%
±10%
> 3
±10%
±7.5%
Deviation of wall thickness and outer diameter of steel pipe supplied according to GB5310 standard
Type of steel pipe
Size of steel pipe mm
Allowable deviation
Normal
Advanced
hot rolled tube
Outer diameter D
≤ 159
± 1.0%(minimum ± 0.50mm)
± 0.75%(minimum ± 0.40mm)
> 159
±1.0%
±0.90%
Wall thickness s
≤ 20
+15.0%(minimum + 0.45mm )- 12.5%-0.35mm)
± 10% (minimum ± 0.30mm)
> 20
±12.5%
±10%
cold drawn pipe
Outer diameter D
10 ~ 30
± 0.40mm
± 0.20mm
> 30 ~ 50
± 0.45mm
± 0.25mm
> 50
+1.0%
±0.75%
Wall thickness s
1.5 ~ 3.0
+15%- 10%
±10%
> 3.0
+12.5%- 10%
±10%
Deviation of wall thickness and outer diameter of steel pipes supplied according to other standards
Project
Standard
Scope
Allowable deviation
Outer diameter
DIN17175
heat pipe
D≤ 100mm
± 0.75%(minimum ± 0.5mm)
D > 100~ 320mm
± 0.9%
Cold pipe: D≤ 120mm
± 0.6%(minimum ± 0.25mm)
ASME SA -192M or ASME SA -209M or ASME SA -210M ASME SA -335M or JIS G 3461
heat pipe
D < 100mm
0.4~ -0.8mm
D≥ 100 ~ < 160mm
0.4~ -1.2mm
D≥ 160 ~ < 200mm
0.4~ -1.8mm
D ≥ 200 mm
0.4~ -2.4mm
Cold pipe
D < 25mm
± 0.10 mm
D≥ 25 ~ < 40mm
± 0.15 mm
D≥ 40 ~ < 50mm
± 0.20 mm
D≥ 50 ~ < 60mm
± 0.25 mm
D≥ 60 ~ < 80mm
± 0.30 mm
ASME SA-106
D 10.3~ 48.3mm
± 0.40 mm
D > 48.3~ 114.3mm
± 0.79 mm
D > 114.3~ 219.1mm
1.59~ -0.79mm
D > 219.1~ 457mm
2.38~ -0.79mm
Wall thickness
DIN17175
D≤ 130mm
S ≤ 2Sn
+15%~-10%
S > 2Sn~4Sn
+12.5%~-10%
S > 4Sn
± 9%
130
S ≤ 0.05D
+17.5%~-12.5%
0.05D < S ≤ 0.11D
± 12.5%
S > 0.11D
± 10%
ASME SA -192M or ASME SA -209M or ASME SA -210M ASME SA -335M or JIS G 3461
heat pipe
S ≥ 2 ~ <2.4mm, and D < 100
+40~0%
S ≥ 2.4 ~ < 3.8mm
+35~0%
S ≥ 3.8 ~ < 4.6mm
+33~0%
S ≥ 4.6mm
+28~0%
Cold pipe
D < 40
S < 2mm
0.4~ 0mm
S ≥ 2mm
+20~0%
D ≥ 40
+22~0%
ASME SA-106
-12.5%
Note: Sn is the standard wall thickness